Cuda 12000 IP Access Switch CudaView Administration Guide
Configuring Upstream Channels 507
What You See
Figure 18-10 Spectrum Group Window
Parameter Descriptions
This table provides a description of the Spectrum Group window parameters
Table 18-10 Spectrum Group Window Parameters.
Parameter Description
Rule Num The number assigned dynamically to the policy.
Threshold Percentage error threshold for this frequency hopping policy
entry.
Interval Threshold interval, in seconds, for this frequency hopping
policy entry.
Profile Num Upstream burst profile number to be used when error
threshold is reached in configured threshold interval time.
Frequency
(MHz)
Center frequency value to be used when error threshold is
reached in configured threshold interval time.
Error Rate The percentage of errors.
Error Count The number of frames with errors.
Total Packets The total number of frames received for each policy.