ADC 410F Istruzioni per gli Interventi Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 79
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
2/2
Pulse output B1 (terminals B1 / B) 2.3
The pulse output is galvanically isolated from the current output and all input circuits.
Setting data and functions can note down on page 0/3.
Please also refer to Sect. 3.2 “Factory settings” and Sect. 2.1 “Combinations of the
binary outputs and inputs”, Fct. 3.07 HARDWARE.
Typical pulse output B1
All operating data and functions can be set:
Display version: IFC 090 D, see Sect. 4 and 5.7, Fct. 1.06 for operator control
Basis version: IFC 090 B, see Sect. 6.2 for operator control
The pulse output can be operated in the active or passive mode.
Active mode: The current output is the internal voltage source,
connection of electronic totalizers (EC)
Passive mode: External DC or AC voltage source required, connection of electronic (EC)
or electromechanical (EMC) totalizers
Digital pulse division, interpulse period is non-uniform. Therefore, if frequency meters or
cycle counters are connected, allow for minimum counting interval:
gate time, counter
1000
P
100% [ Hz]
Connection diagrams, see Sect. 2.6: diagrams 3 4 5 9
B2 status output B2
or control input B2
B
chassis ground, binary
outputs and inputs
B1 pulse output B1 (or status
output, control input)
Vedere la pagina 12