ADC Cuda 12000 Informazioni Techniche Pagina 571

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 652
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 570
Cuda 12000 IP Access Switch CLI Reference Guide
snmp-server host 567
chassis-fault A physical fault occurred within the chassis, its modules, its
associated fan tray, its power source, or its clock sources. This
notification type has a “critical” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
chassis-fault-cleared A physical fault that occurred within the chassis, its modules
its fan tray, its power source, or its clock sources has cleared.
This notification type has a “notice” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
cold-start The SNMP entity on the Cuda 12000, acting in an agent role,
is reinitializing itself and that its configuration may have been
altered. This notification type has a “notice” priority. Refer to
the description of the event-config reporting command for
more information on event priorities.
dereg-modems A number or percentage of modems have deregistered over
the deregistration time interval. This notification type has a
“warning” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
dhcp-relay-not-configured A DHCP configuration error occurred. This notification type
has a “warning” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
docs-bpi-init A BPI initialization attempt failed during the cable modem
registration process and was detected by the CMTS. This
notification type has an “info” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
docs-bpkm A baseline privacy key management (BPKM) operation failed
and was detected by the CMTS. This notification type has an
“error” priority. Refer to the description of the event-config
reporting command for more information on event priorities.
docs-dcc-ack-fail A dynamic channel change acknowledgement failed during
the dynamic channel change process in the CMTS. This
notification type has a “warning” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
Notification Type Indicates that...
Vedere la pagina 570
1 2 ... 566 567 568 569 570 571 572 573 574 575 576 ... 651 652

Commenti su questo manuale

Nessun commento