ADC Cuda 12000 Informazioni Techniche Pagina 573

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 652
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 572
Cuda 12000 IP Access Switch CLI Reference Guide
snmp-server host 569
docs-init-rsp-fail A registration response failed during the cable modem
initialization process and was detected by the CMTS. This
notification type has a “warning” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
duplicate-addr A duplicate IP address has been detected. This notification
type has a “notice” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
icl-state-change A change in the ICL link to a peer has occurred. This
notification type has a “notice” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
isp-addr-high The free IP address count exceeded the upper threshold for
the specified ISP. This notification type has a “notice” priority.
Refer to the description of the event-config reporting
command for more information on event priorities.
isp-addr-low The free address count fell below the lower threshold for the
specified ISP. This notification type has a “notice” priority.
Refer to the description of the event-config reporting
command for more information on event priorities.
ldap-failed A directory server access failure occurred. This notification type
has a “notice” priority. Refer to the description of the
event-config reporting command for more information on
event priorities.
ldap-restored Directory server access is operational after a failure. This
notification type has a “notice” priority. Refer to the
description of the event-config reporting command for
more information on event priorities.
link-down Signifies that the SNMP entity on the Cuda 12000, acting in
an agent role, has detected that the communication link is
about to go down. This notification type has an “error”
priority. Refer to the description of the event-config
reporting command for more information on event priorities.
link-up Signifies that the SNMP entity on the Cuda 12000, acting in
an agent role, has detected that the communication link is
about to come up. This notification type has a “notice”
priority. Refer to the description of the event-config
reporting command for more information on event priorities.
Notification Type Indicates that...
Vedere la pagina 572
1 2 ... 568 569 570 571 572 573 574 575 576 577 578 ... 651 652

Commenti su questo manuale

Nessun commento