Cuda 12000 IP Access Switch CLI Reference Guide
chassis-config 79
Example 1
In this example, the user displays the chassis configuration and sets the chassis ID:
cli:root# show chassis-config
Chassis Number: 101
Chassis Id: 1
Cluster Id: 0
Primary Manager Slot: 13
Secondary Manager Slot: None
Scope: Cluster
cli:root# chassis-config 101 chassisid 100
cli:root# slot 1/13
mode: slot(1/13)
cli:root:slot(1/13)# save
Saving slot: 1/13 ..
Save request passed for slot 1/13
cli:root# root
mode: root
cli:root# show chassis config
Chassis Number: 101
Chassis Id: 100
Cluster Id: 0
Primary Manager Slot: 13
Secondary Manager Slot: None
Scope: Cluster
Example 2
In this example, the user forces the primary management module into the secondary role,
thereby forcing the secondary management module into the primary role:
cli# show chassis-config
Chassis Number: 101
Chassis Id: 1
Cluster Id: 0
Primary Manager Slot: 13
Secondary Manager Slot: 14
Scope: Cluster
cli# chassis-config 101 manager secondary
Connection to 192.168.222.200 refused or closed!
Related Commands
show chassis-config on page 386
Vedere la pagina 82