MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
16
MYXPM6021*
Form #: CSI-D-685 Document 011
7 Operating Conditions
7.1 System Control Signals
7.1.1 VDCIN_SENSE
InputvoltageislimitedtothemaximuminputvoltageviatheresistordivideroftheAC/DCadapter.
7.1.2 ACPRESENT
ACPRESENT is an active high dedicated output signal that indicates the AC/DC adapter or USB DCP/CDP/ACA
(CHGDET_B=0)isconnectedtoavalidvoltage.
7.1.3 VBUS_SENSE
USBinputvoltagedetection.
7.1.4 CHGDET_B
USBDCPdetectionfromUSBPHYtoMYXPM6021.(0=USBDCP/CDP/ACA).
7.1.5 VSYS1/2
Inputpowersuppliesandinputvoltagesupervision.
7.1.6 CHGSTAT
InputtoMYXPM6021indicatingthebatterychargerstatusandfaultindicatorfromchargerIC.
7.1.7 ILIM[1:0]
OutputsignalsprovidinginformationtheexternalconnectedpowersourceslikeACadapter,USBDCP/CDP/ACAand
USBSDP).
7.1.8 I2C_CLK
I2CclocksignalfromSoCtoMYXPM6021.
7.1.9 I2C_DATA
I2CdataconnectionbetweenSoCandMYXPM6021.