Parameter Description Test Conditions Min Typ Max Unit
Transient load current prole 5-250mA 200 ns
Transient droop
1
75-1820mA
5-250mA
40 mV
Transient overshoot
2
1820-75mA
250-5mA
40 mV
Ton Turn on time 2 ms
Rpd Discharge impedance Vout ..0V 20 Ω
IQ_ON Quiescent Current in
On Mode
No load 50 μA
Normal Mode – Synchronous rectication (PWM)
Maximum Output Current (Imax) 1900 mA
ILIMIT Current limitation Cycle by cycle 1.3*Imax mA
Efciency at VSYS = 3.7V &
Tamb=60°C
with proposed external
components and
PCB layout
See Figure 13
Sleep Mode – Pulse skipping (PSK)
Efciency at VSYS = 3.7V &
Tamb=60°C
with proposed external
components and
PCB layout
See Figure 13