ADC 6021 Specifiche Pagina 22

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 113
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 21
MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
22
MYXPM6021*
Form #: CSI-D-685 Document 011
7.2 MYXPM6021 Power States
Followingisabriefdescriptionofthesestates:
• OFF:Nopoweratall.Theplatformcoincellhasnovalidpower.
• COIN:COINdomainispoweredandnotunderreset.Coindomainreferstoasmalllogicportioninside
MYXPM6021,whichgetsaresetsignalandsupplyfromthecoincellorasupercap.Theselogicregistersretaindata
whenMYXPM6021supplyfailsorPMICgoesunderthePOR.Theseregisteraresittingontheanalogside.TheCOIN
stateisnotrelatedtoanyoperationinthePMICandisnotcoded.Itrepresentsjustapossiblesupplyscenario.
• RESET:ThedigitalcorewhichisnotsuppliedfromtheCOINisunderPORduetothefactthattheVSYSinputhas
notcrossedyetthePORreleasethreshold.
• OTP:JustafterPORisreleasedMYXPM6021goesintoOTPstateandreadstheOTP.Inthisstateallthetrimming,
calibration,powersequencing,andplatformvariantdataisreadandcopiedintotheoperationalregisters.Thisstateis
crossedonlyduringrstpoweruporwhenMYXPM6021isforcedbyPORorsoftresettogobackintoRESETstate.
• EEPROM:Fordebuggingpurposeorasafallbacksolutionintheeldit’spossibletooverwritetheoperational
registersviaanexternalEEPROM.ThisstepisalwaysperformedfromMYXPM6021aftertheOTPstateandisdone
onceduringrstpowerupiftheEEPROMcontains.ItisassumedthattheEEPROMissuppliedatthetimeofthe
access.
• G3:Thisstatecorrespondstoanon-validsystemsupplyVSYS(VSYS<VSYSREF=3.0V).VSYSisnotconsidered
tobegoodenoughforbooting.
• SOC_G3:Thisisbydenitionthe“systempowerdown”state.Applicationwillbemainlyloopingbetweenactive
stateandthisstate.VSYSvalideventmakesthePMICgoingfromG3toSOC_G3state.Criticaleventsandpower
buttoncanleadthePMICtothisstate.Onlyinthisstateitispossibletobesensitivetotheexternalwakeupevents.
Figure 3: MYXPM6021 power up states
MYXPM6021willissueanundervoltageagwhenVSYSwillfallbelowthe2.7Vthreshold.Inthiscaseashutdownwillbe
executedbringingdownallrailsinanorderedfashion.ThenalstatewillbeG3.